Range of wires

Range of wires PDF

Bare wires
Conductor

Rectangular wire

  • Cu according to DIN EN 13601

round wire

  • Cu according to DIN EN 13602
Dimension

rectangular wire

according to DIN EN 60317-0-2
  • width: 3,35 mm – 30,00 mm
  • thickness: 1,00 mm – 7,00 mm, max.
    • 20,00 mm x 7,00 mm
    • 30,00 mm x 5,00 mm
    • 25,00 mm x 6,00 mm

round wire

according to DIN EN 60317-0-1

  • Ø 3,80 – 7,00 mm
Application
  • conductor to the further insulation
  • rotor bares
Rectangular and round wiresinsulated with polyimide film Kapton®
Conductor

rectangular wire

  • Cu according to DIN EN 13601

round wire

  • Cu according to DIN EN 13602
Dimension

rectangular wire

according to DIN EN 60317-0-2

  • width: 3,35 mm – 16,00 mm
  • thickness: 1,00 mm – 5,00 mm

round wire

according to DIN EN 60317-0-1

  • Ø 1,00 mm – 6,00 mm
Insulation/
modality
  • DIN EN 60317-44 rectangular
  • DIN EN 60317-43 round
    according to customer specifications

polyimide film

  • also corona resistant
  • FEP-coated and heat sealed
    temperature index 240
Increase
by insulation
0,15 mm; 0,23 mm; 0,30 mm; 0,35 mm
Number of layers/
sheathing
  • 1 layer
  • 2 opposed layers
Overlap

stepless variable

  • max. 75 %
Application traction motors, motors for special applications and motors for high temperature applications
Comments insulated round wire is not applicable for pull-in technique
Rectangular and round wiresinsulated with mica film
Conductor

rectangular wire

  • Cu according to DIN EN 13601

round wire

  • Cu according to DIN EN 13602
Dimension

rectangular wire

according to DIN EN 60317-0-2
  • width: 3,35 mm – 25,00 mm
  • thickness: 1,00 mm – 7,00 mm

round wire

according to DIN EN 60317-0-1

  • Ø 0,65 mm – 3,50 mm
Insulation/
modality
  • according to customer specifications
  • mica film with PET-substrate,
    mica and epoxy binder material
    temperature index 155
  • combinations with varnished wire and/or PET  lm possible
  • high-temperature resistant mica tape with or without PET film
Increase
by insulation
according to customer specifications
Number of layers/
sheathing
  • 1 - 4 layers
  • concurrent or opposed
  • further layers on inquiry
Overlap

end to end, stepless variable

  • max. 75 %
Application high and low voltage machines, frequency-/inverter resistant motors, motors for high temperature application,  fire proofed cable, transformers
Comments insulated round wire is not applicable for pull-in technique
Rectangular and round wiresinsulated with paper or aramide paper Nomex®
Conductor

rectangular wire

Cu according to DIN EN 13601

round wire

Cu according to DIN EN 13602

Dimension

rectangular wire

according to DIN EN 60317-0-2

  • width: 3,35 mm – 25,00 mm
  • thickness: 1,00 mm – 6,00 mm

round wire

according to DIN EN 60317-0-1, bare, varnished

  • Ø: 0,80 mm – 5,00 mm
Insulation/
modality
  • DIN EN 60317-27 bzw. -53 rectangular
  • DIN EN 60317-52 round, according to customer specifications
  • craft paper, also thermally stabilized
  • Nomex® temperature index 220
  • possible in combination with varnished wire
Increase
by insulation
according to customer specifications
Number of layers/
sheathing
  • 1 - 8 layers
  • concurrent or opposed
  • further layers on inquiry
Overlap

end to end, stepless variable

  • rectangular wire max. 80 %
  • round wire max. 50 %
Application
  • transformerwindings
  • inductor coils
Comments insulated round wire is not applicable for pull-in technique
Rectangular wiresenamelled
Conductor

rectangular wire

Cu-ETP according to DIN EN 13601

Dimension

rectangular wire

according to DIN EN 60317-0-2

  • width: 3,35 mm – 14,00 mm
  • thickness: 1,00 mm – 5,00 mm
Insulation/
modality
  • DIN EN 60317-0-2
  • DIN EN 60317-58
  • polyamidimide temperature index 220
Increase
by insulation
  • grade 1: 0,06 mm – 0,11 mm
  • grade 2: 0,12 mm – 0,17 mm
Application motors, generators, transformers
Rectangular and round wires insulated with glass fibre yarn and/or blended yarn with glass fibres and polyester (GP) bare, varnished
Conductor

rectangular wire

  • Cu according to DIN EN 13601

round wire

  • Cu according to DIN EN 13602
  • Al 99,5 according to EN 573-3 on inquiry
Dimension

rectangular wire

according to DIN EN 60317-0-2 bare, varnished

  • width: 3,00 mm – 20,00 mm
  • thickness: 1,00 mm – 5,00 mm

round wire

according to DIN EN 60317-0-1 bare, varnished

  • Ø 0,50 mm – 5,00 mm
Insulation/
modality
  • DIN EN 60317-31 rectangular
  • DIN EN 60317-32 rectangular
  • DIN EN 60317-0-6 round, according to customer specifications
  • bare or varnished wire
  • glass fibre yarn and/or blended yarn from glass fibres and polyester, impregnated with epoxy resin temperature index 155 or polyesterimide temperature index 180
Increase
by insulation
  • rectangular wire: 0,12 mm – 0,55 mm
  • round wire: 0,12 mm – 0,40 mm
Number of layers/
sheathing
  • 1 layer
  • 2 opposed layers
Application traction motors, generators, high voltage, motors, motors for special applications
Comments insulated round wire is not applicable for pull-in technique
Litz wireinsulated with mica and/or PET film
Conductor

single round wire

Cu according to DIN EN 13602

  • bare or varnished
Dimension

single wire

according to DIN EN 60317-0-1

  • Ø 0,20 mm – 0,80 mm
  • profile of flex wires: 1,5 mm² - 70 mm²
Insulation/
modality

according to customer specifications

  • PET- film
  • mica film
Increase
by insulation
according to customer specifications
Number of layers/
sheathing
  • 1 to 3 concurrent layers
  • 2 opposed layers
Overlap stepless variable
  • min 30 % / max 80 %
Application HF-motors, inductors, transformers